Performance
Insulation
- Thermal insulation (Best) – U f
- 1.8 W/m²K
- Thermal insulation – Uw
- 1.3 W/m²K
- Uw Dependencies
- Frame-vent: Ug 1.0W/m²K, warm edge spacer, @1.23x1.48m (102mm sight line), 36mm glass
Comfort
- Air tightness
- Class 4 (600Pa)
- Water tightness
- Class E900 (900Pa)
- Wind load resistance
- Class C5 (2000Pa)
- Acoustics – Rw(C;Ctr)
- 42 (-2;-4) dB
- Durability
- Class 3 (20000 cycles)
Safety & Security
- Burglar resistance
- PAS 24 · RC2 · RC3
- Fire resistance
- EI₁ 30 · EI₂ 30 · EI₂ 60 · EW 30
Properties
Sightlines
- Min. frame width (inward opening)
- 51 mm
- Min. vent width (inward opening)
- 33 mm
- Min. frame-vent width (inward opening)
- 89 mm
- Min. frame width (outward opening)
- 17.5 mm
- Min. vent width (outward opening)
- 76 mm
- Min. frame-vent width (outward opening)
- 93.5 mm
- Depth frame
- 68 mm
- Depth Vent
- 77 mm
- Depth frame-vent
- 77 mm
Glazing
- Rebate height
- 25 mm
- Glazing method
- Dry glazing · Siliconized glazing · Internal glazing · External glazing · Glazing bead
- Min. glass thickness – vent
- 4 mm
- Max. glass thickness – vent
- 63 mm
* Parameters and properties may vary depending on the profile selection.